Parameters
7.2 Parameter list
p1059[0...n]

Jog 2 speed setpoint / Jog 2 n_set

Access level: 2
Can be changed: T
Unit group: 3_1
Min:
-210000.000 [rpm]
Description:
Sets the speed for jog 2.
Jogging (JOG) is level-triggered, and allows the motor to be incrementally traversed.
Dependency:
See also: p1055, p1056
p1063[0...n]

Setpoint channel speed limit / Setp_chan n_lim

Access level: 3
Can be changed: T, U
Unit group: 3_1
Min:
0.000 [rpm]
Description:
Sets the speed limit effective in the setpoint channel.
Dependency:
See also: p1082, p1083, p1085, p1086, p1088
p1070[0...n]

CI: Main setpoint / Main setpoint

G120X_DP,
Access level: 3
G120X_PN
Can be changed: T
Unit group: -
Min:
-
Description:
Sets the signal source for the main setpoint.
Examples:
r1024: Fixed speed setpoint effective
r1050: Motor. potentiometer setpoint after the ramp-function generator
Dependency:
See also: p1071, r1073, r1078
NOTICE
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1070[0...n]
CI: Main setpoint / Main setpoint
G120X_USS
Access level: 3
Can be changed: T
Unit group: -
Min:
-
622
Calculated: -
Scaling: -
Unit selection: p0505
Max:
210000.000 [rpm]
Calculated: -
Scaling: -
Unit selection: p0505
Max:
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: -
Max:
-
Calculated: -
Scaling: p2000
Unit selection: -
Max:
-
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3001, 3030
Factory setting:
-150.000 [rpm]
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3040
Factory setting:
210000.000 [rpm]
Data type: Unsigned32 /
FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3001, 3030
Factory setting:
[0] 2050[1]
[1] 0
[2] 0
[3] 0
Data type: Unsigned32 /
FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 3001, 3030
Factory setting:
[0] 755[0]
[1] 0
[2] 0
[3] 0
SINAMICS G120X converter