Parameters
7.2 Parameter list
p3326[0...n]
Fluid flow machine power point 4 / Fluid_mach P4
Access level: 2
Can be changed: T, U
Unit group: -
Min:
0.00
Description:
For the energy-saving display of a fluid-flow machine, a typical flow characteristic P = f(n) with 5 points along the
characteristic is required.
This parameter specifies the power (P) of point 4 as a [%].
Dependency:
See also: r0041, p3320, p3321, p3322, p3323, p3324, p3325, p3327, p3328, p3329
Note
The reference value for power and speed is the rated power/rated speed.
The energy saved is displayed in r0041.
p3327[0...n]
Fluid flow machine speed point 4 / Fluid_mach n4
Access level: 2
Can be changed: T, U
Unit group: -
Min:
0.00
Description:
For the energy-saving display of a fluid-flow machine, a typical flow characteristic P = f(n) with 5 points along the
characteristic is required.
This parameter specifies the speed (n) of point 4 as a [%].
Dependency:
See also: r0041, p3320, p3321, p3322, p3323, p3324, p3325, p3326, p3328, p3329
Note
The reference value for power and speed is the rated power/rated speed.
The energy saved is displayed in r0041.
p3328[0...n]
Fluid flow machine power point 5 / Fluid_mach P5
Access level: 2
Can be changed: T, U
Unit group: -
Min:
0.00
Description:
For the energy-saving display of a fluid-flow machine, a typical flow characteristic P = f(n) with 5 points along the
characteristic is required.
This parameter specifies the power (P) of point 5 as a [%].
Dependency:
See also: r0041, p3320, p3321, p3322, p3323, p3324, p3325, p3326, p3327, p3329
Note
The reference value for power and speed is the rated power/rated speed.
The energy saved is displayed in r0041.
p3329[0...n]
Fluid flow machine speed point 5 / Fluid_mach n5
Access level: 2
Can be changed: T, U
Unit group: -
Min:
0.00
836
Calculated: -
Scaling: -
Unit selection: -
Max:
100.00
Calculated: -
Scaling: -
Unit selection: -
Max:
100.00
Calculated: -
Scaling: -
Unit selection: -
Max:
100.00
Calculated: -
Scaling: -
Unit selection: -
Max:
100.00
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
Factory setting:
92.00
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
Factory setting:
75.00
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
Factory setting:
100.00
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: -
Factory setting:
100.00