Parameters
7.2 Parameter list
r29706

CO: Temperature sensor exciting current output / TempSen I_out

Access level: 2
Can be changed: -
Unit group: -
Min:
- [%]
Description:
Current output to temperature sensor in percent of 20mA.
Note
This CO parameter may connect to the analog output source set(e.g. p771[x]), which is the AO channel of sensor
connected.
r29707

CO: Temperature sensor resistance value / TempSen R

Access level: 3
Can be changed: -
Unit group: -
Min:
- [ohm]
Description:
Display the actual resistance value of the temperature sensor.
p29708

Temperature sensor exiting current set / TempSen I_exit

Access level: 4
Can be changed: T, U
Unit group: -
Min:
0.00 [%]
Description:
Sets the exciting current of temperature sensor.
p60000

PROFIdrive reference speed reference frequency / PD n_ref f_ref

G120X_DP,
Access level: 2
G120X_PN
Can be changed: T
Unit group: -
Min:
6.00 [rpm]
Description:
Sets the reference quantity for speed and frequency.
All speeds or frequencies specified as relative value are referred to this reference quantity.
The reference quantity corresponds to 100% or 4000 hex (word) or 4000 0000 hex (double word).
The following applies: reference frequency (in Hz) = reference speed (in ((rpm) / 60) x pole pair number)
Dependency:
See also: p2000
NOTICE
When the reference speed / reference frequency is changed, short-term communication interruptions may occur.
934
Calculated: -
Scaling: -
Unit selection: -
Max:
- [%]
Calculated: -
Scaling: -
Unit selection: -
Max:
- [ohm]
Calculated: -
Scaling: -
Unit selection: -
Max:
100.00 [%]
Calculated: CALC_MOD_ALL Data type: FloatingPoint32
Scaling: -
Unit selection: -
Max:
210000.00 [rpm]
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
Factory setting:
- [%]
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
Factory setting:
- [ohm]
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
Factory setting:
50.00 [%]
Dynamic index: -
Function diagram: -
Factory setting:
1500.00 [rpm]
SINAMICS G120X converter

Advertisement

Table of Contents
loading

Table of Contents