Parameters
7.2 Parameter list
r8573[0...39]

Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set

Access level: 4
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Note
For a value = 9999999, the following applies: The read operation is still running.
r8585

Macro execution actual / Macro executed

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the macro currently being executed on the drive object.
Dependency:
See also: p0015, p1000, r8570, r8571, r8572, r8573
p8805
Identification and maintenance 4 configuration / I&M 4 config
G120X_PN
Access level: 3
Can be changed: T, U
Unit group: -
Min:
0
Description:
Sets the configuration for the content of identification and maintenance 4 (I&M 4, p8809).
Value:
0:
1:
Dependency:
For p8805 = 0, if the user writes at least one value in p8809[0...53], then p8805 is automatically set to = 1.
When p8805 is reset = 0, then the content of the factory setting is set in p8809.
Note
For p8805 = 0:
PROFINET I&M 4 (p8809) contains the information for the SI change tracking.
For p8805 = 1:
PROFINET I&M 4 (p8809) contains the values written by the user.
p8806[0...53]
Identification and Maintenance 1 / I&M 1
G120X_PN
Access level: 3
Can be changed: T, U
Unit group: -
Min:
-
Description:
Parameters for the PROFINET data set "Identification and Maintenance 1" (I&M 1).
This information is known as "System identifier" and "Location identifier".
Dependency:
See also: p8807, p8808
NOTICE
Only characters belonging to the standard ASCII character set may be used (32 dec to 126 dec).
878
Standard value for I&M 4 (p8809)
User value for I&M 4 (p8809)
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: -
Max:
1
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Data type: Unsigned32
Dynamic index: -
Function diagram: -
Factory setting:
-
Data type: Unsigned16
Dynamic index: -
Function diagram: -
Factory setting:
-
Data type: Integer16
Dynamic index: -
Function diagram: -
Factory setting:
0
Data type: Unsigned8
Dynamic index: -
Function diagram: -
Factory setting:
SINAMICS G120X converter