The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8924

PN DHCP Mode / PN DHCP mode

G120X_PN
Access level: 3
Can be changed: T, U
Unit group: -
Min:
0
Description:
Sets the DHCP mode for the onboard PROFINET interface on the Control Unit.
The actual DHCP mode is displayed in r8934.
Value:
0:
2:
3:
Dependency:
See also: p8925, r8934
NOTICE
When the DHCP mode is active (p8924 not equal to 0), then PROFINET communication via this interface is no longer
possible!
Note
The interface configuration (p8920 and following) is activated with p8925.
The active DHCP mode is displayed in parameter r8934.
The parameter is not influenced by setting the factory setting.
p8925

Activate PN interface configuration / PN IF config

G120X_PN
Access level: 3
Can be changed: T, U
Unit group: -
Min:
0
Description:
Setting to activate the interface configuration for the onboard PROFINET interface on the Control Unit.
p8925 is automatically set to 0 at the end of the operation.
Value:
0:
1:
2:
3:
Dependency:
See also: p8920, p8921, p8922, p8923, p8924
NOTICE
When the DHCP mode is active (p8924 > 0), then PROFINET communication via this interface is no longer possible!
Note
For p8925 = 2:
The interface configuration (p8920 and following) is saved and activated after the next POWER ON.
For p8925 = 3:
The factory setting of the interface configuration is loaded after the next POWER ON.
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
DHCP off
DHCP on, identification using MAC address
DHCP on, identification via name of station
No function
Reserved
Activate and save configuration
Delete configuration
Calculated: -
Scaling: -
Unit selection: -
Max:
3
Calculated: -
Scaling: -
Unit selection: -
Max:
3
Parameters
7.2 Parameter list
Data type: Integer16
Dynamic index: -
Function diagram: -
Factory setting:
0
Data type: Integer16
Dynamic index: -
Function diagram: -
Factory setting:
0