r3120[0...63]

Component fault / Comp fault

Access level: 3
Can be changed: -
Unit group: -
Min:
0
Description:
Displays the component of the fault which has occurred.
Value:
0:
1:
2:
3:
Dependency:
See also: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136, r3122
Note
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the fault buffer and the assignment of the indices is shown in r0945.
r3121[0...63]

Component alarm / Comp alarm

Access level: 3
Can be changed: -
Unit group: -
Min:
0
Description:
Displays the component of the alarm which has occurred.
Value:
0:
1:
2:
3:
Dependency:
See also: r2110, r2122, r2123, r2124, r2125, r2134, r2145, r2146, r3123
Note
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the alarm buffer and the assignment of the indices is shown in r2122.
r3122[0...63]

Diagnostic attribute fault / Diag_attr fault

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the diagnostic attribute of the fault which has occurred.
Bit field:
Bit
00
15
16
17
18
19
20
Dependency:
See also: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136, r3120
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
No assignment
Control Unit
Power Module
Motor
No assignment
Control Unit
Power Module
Motor
Signal name
Hardware replacement recommended
Message has gone
PROFIdrive fault class bit 0
PROFIdrive fault class bit 1
PROFIdrive fault class bit 2
PROFIdrive fault class bit 3
PROFIdrive fault class bit 4
Calculated: -
Scaling: -
Unit selection: -
Max:
3
Calculated: -
Scaling: -
Unit selection: -
Max:
3
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
High
High
High
High
High
Parameters
7.2 Parameter list
Data type: Integer16
Dynamic index: -
Function diagram: 8060
Factory setting:
-
Data type: Integer16
Dynamic index: -
Function diagram: 8065
Factory setting:
-
Data type: Unsigned32
Dynamic index: -
Function diagram: 8060
Factory setting:
-
0 signal
FP
No
-
No
-
Low
-
Low
-
Low
-
Low
-
Low
-
829