6.5.1.4

Fixed speed setpoint as setpoint source

Function description
Figure 6-44
The converter makes a distinction between two methods when selecting the fixed speed
setpoints:
● Direct selection (p1016 = 1)
● Binary selection (p1016 = 2)

Directly selecting a fixed speed setpoint

Figure 6-45
Table 6-80
p1023
0
0
0
0
0
0
0
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Fixed speed setpoint as setpoint source

Direct selection of the fixed speed setpoint

Resulting setpoint

p1022
p1021
0
0
0
0
0
1
0
1
1
0
1
0
1
1
6.5 Setpoints and setpoint processing
p1020
Resulting setpoint
0
0
1
p1001
0
p1002
1
p1001 + p1002
0
p1003
1
p1001 + p1003
0
p1002 + p1003
Advanced commissioning
333