Chapter 3
Turn Up Node
Stop. You have completed this procedure.

NTP-B34 Create Ethernet RMON Alarm Thresholds

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Log into the ONS 15327 node where you want to set up SNMP. See the
Step 1
on page 2-23
In node view, click the Provisioning > Ether Bridge > Thresholds tabs.
Step 2
Click Create.
Step 3
The Create Ether Threshold dialog box opens
Figure 3-5
From the Slot pull-down menu, choose the appropriate Ethernet card.
Step 4
From the Port pull-down menu, choose the applicable port on the Ethernet card you selected.
Step 5
From the Variable pull-down menu, choose the variable. See
Step 6
Ethernet threshold variables available in this field.
Step 7
From the Alarm Type pull-down menu, indicate whether the event will be triggered by the rising
threshold, falling threshold, or both the rising and falling thresholds.
March 2003
This procedure sets up remote monitoring (RMON) to allow network
management systems to monitor Ethernet ports.
None
NTP-B24 Verify Card Installation, page 3-2
As needed
Onsite or remote
Provisioning or higher
for instructions. If you are already logged in, continue with Step 2.
Creating RMON Thresholds
NTP-B34 Create Ethernet RMON Alarm Thresholds
"DLP-B60 Log into CTC" task
(Figure
3-5).
Table 3-2 on page 3-24
Cisco ONS 15327 Procedure Guide, R4.0
for a list of the
3-23