Dlp-B226 Modify Alarm And Condition Filtering Parameters; Figure 6-14 Alarm Filter Dialog Box General Tab - Cisco ONS 15327 Procedure Manual

Hide thumbs Also See for ONS 15327:
Table of Contents

Advertisement

NTP-B168 Enable, Modify, or Disable Alarm Severity Filtering

DLP-B226 Modify Alarm and Condition Filtering Parameters

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
At the node, network, or card view, click the Alarms tab.
Step 1
Click the Filter button at the lower-left of the bottom toolbar.
Step 2
The Alarm Filter Dialog box appears, showing the General tab

Figure 6-14 Alarm Filter Dialog Box General Tab

In the General tab Show Severity area, you can choose which alarm severities will show through the
alarm filter and provision a snapshot period during which alarms will appear. To change the alarm
severities shown in the filter, continue with
Step
In the Show Severity area, click the check boxes for the severities [Critical (CR), Major (MJ), Minor
Step 3
(MN), or Not-Alarmed (NA)] you want to be reported at the network level. Leave severity check boxes
deselected (unchecked) to keep them from appearing.
Note
Cisco ONS 15327 Procedure Guide, R4.0
6-28
Use this task change alarm and condition reporting in all network nodes.
None
DLP-B225 Enable Alarm Filtering, page 6-27
DLP-B60 Log into CTC, page 2-23
As needed
Onsite or remote
Retrieve or higher
4.
When alarm filtering is disabled, all alarms show.
(Figure
Step
3. To change the alarm time period, continue with
Chapter 6
Manage Alarms
6-14).
November 2004

Advertisement

Table of Contents
loading