Dlp-B111 Changing The Maximum Number Of Session Entries For Alarm History - Cisco ONS 15327 Procedure Manual

Hide thumbs Also See for ONS 15327:
Table of Contents

Advertisement

Chapter 6
Manage Alarms
Click Retrieve.
Step 8
The window displays raised and cleared alarm messages (and events, if selected).
Step 9
Tip
Return to your originating procedure (NTP).
Step 10

DLP-B111 Changing the Maximum Number of Session Entries for Alarm History

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
From the Edit menu choose Preferences.
Step 1
The CTC Preferences Dialog box appears
Figure 6-4
Click the up or down arrow buttons next to the Maximum History Entries field to change the entry.
Step 2
Click Apply and OK.
Step 3
November 2004
Double-click an alarm in the alarm table or a condition in the history table to display the view
that corresponds to the alarm message. For example, double-clicking a card alarm takes you to
card view. In network view, double-clicking a node alarm takes you to node view.
This task changes the maximum number of session entries included in the
alarm history. Use this task to extend the history list in order to save
information for future reference or troubleshooting.
None
DLP-B60 Log into CTC, page 2-23
As needed
Onsite or remote
Provisioning
CTC Preferences Dialog Box
NTP-B196 View Alarms, History, Events, and Conditions
(Figure
6-4).
Cisco ONS 15327 Procedure Guide, R4.0
6-9