Ntp-B174 Linear Adm Network Acceptance Test - Cisco ONS 15327 Procedure Manual

Hide thumbs Also See for ONS 15327:
Table of Contents

Advertisement

NTP-B174 Linear ADM Network Acceptance Test

Verify that timing has been set up at each linear node. If not, complete the
Step 6
procedure on page
Complete the
Step 7
Stop. You have completed this procedure.
NTP-B174 Linear ADM Network Acceptance Test
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Log into an ONS 15327 on the linear ADM network you are testing. See the
Step 1
task on page 2-23
From the View menu choose Go to Network View.
Step 2
Click the Alarms tab.
Step 3
a.
b.
Complete the
Step 4
drive.
Click the Conditions tab. Verify that the network does not have any unexplained conditions. If
Step 5
unexplained conditions are present, resolve them before continuing. Refer to the Cisco ONS 15327
Troubleshooting Guide.
Complete the
Step 6
hard drive.
Display a linear ADM node in node view.
Step 7
Create a test circuit from that node to an adjacent linear ADM node.
Step 8
Cisco ONS 15327 Procedure Guide, R4.0
4-12
3-16. If a node is using line timing, use its working OC-N card as the timing source.
"NTP-B174 Linear ADM Network Acceptance Test" procedure on page
This procedure tests a linear ADM network.
Test set/cables appropriate to the test circuit you will create
NTP-B38 Provision a Linear ADM Network, page 4-11
As needed
Onsite
Provisioning or higher
for instructions. If you are already logged in, continue with Step 2.
Verify that the network does not have any unexplained alarms. If unexplained alarms are present,
resolve them before continuing. Refer to the Cisco ONS 15327 Troubleshooting Guide.
Ensure that the alarm filter icon in the lower right corner is not indented. If so, click it once to turn
it off. When you are done checking for alarms, click the icon again to turn alarm filtering back on.
See the
"DLP-B227 Disable Alarm Filtering" task on page 6-30
"DLP-B139 Export CTC Data" task on page 6-3
"DLP-B139 Export CTC Data" task on page 6-3
For DS-1 circuits, complete the
procedure on page
5-5. When you set the circuit state, choose IS and check the Apply to drop ports
check box.
For DS-3 circuits, complete the
procedure on page
5-18. When you set the circuit state, choose IS and check the Apply to drop
ports check box.
to export alarm data to a file on your hard
"NTP-B181 Create an Automatically Routed DS-1 Circuit"
"NTP-B184 Create an Automatically Routed DS-3 Circuit"
Chapter 4
Turn Up Network
"NTP-B28 Set Up Timing"
4-12.
"DLP-B60 Log into CTC"
for instructions.
to export condition data to a file on your
March 2003

Advertisement

Table of Contents
loading