Ntp-B173 Point-To-Point Network Acceptance Test; Figure - Cisco ONS 15327 Procedure Manual

Hide thumbs Also See for ONS 15327:
Table of Contents

Advertisement

Chapter 4
Turn Up Network

NTP-B173 Point-to-Point Network Acceptance Test

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Log into one of the point-to-point nodes. See the
Step 1
instructions. If you are already logged in, continue with Step 2.
From the View menu choose Go to Network View.
Step 2
Click the Alarms tab.
Step 3
a.
b.
Complete the
Step 4
Click the Conditions tab. Verify that the network does not have any unexplained conditions. If
Step 5
unexplained conditions are present, resolve them before continuing. Refer to the Cisco ONS 15327
Troubleshooting Guide.
Complete the
Step 6
On the network map, double-click one point-to-point node to display it in node view.
Step 7
Create a test circuit from the login node to the other point-to-point node:
Step 8
Configure the test set for the test circuit type you created:
Step 9
Step 10
Verify the integrity of all patch cables that will be used in this test by connecting one end to the test set
transmit (Tx) connector and the other end to the test set receive (Rx) connector. If the test set does not
run error-free, check the cable for damage and check the test set to make sure it is set up correctly before
going to
March 2003
This procedure tests a point-to-point network.
Test set/cables appropriate to the test circuit you will create
NTP-B124 Provision a Point-to-Point Network, page 4-4
As needed
Onsite
Provisioning or higher
Verify that the network does not have any unexplained alarms. If unexplained alarms are present,
resolve them before continuing. Refer to the Cisco ONS 15327 Troubleshooting Guide.
Ensure that the alarm filter icon in the lower right corner is not indented. If so, click it once to turn
it off. When you are done checking for alarms, click the icon again to turn alarm filtering back on.
See the
"DLP-B227 Disable Alarm Filtering" task on page 6-30
"DLP-B139 Export CTC Data" task on page 6-3
"DLP-B139 Export CTC Data" task on page 6-3
For DS-1 circuits, complete the
procedure on page
5-5. When you set the circuit state, choose IS and check the Apply to drop ports
check box.
For DS-3 circuits, complete the
procedure on page
5-18. When you set the circuit state, choose IS and check the Apply to drop
ports check box.
DS-1—If you are testing an unmuxed DS-1, you must have a DSX-1 panel or a direct DS-1 interface
into the ONS 15327 through the AMP Champ connectors on the Mechanical Interface Card (MIC).
Set the test set for DS-1. For information about configuring your test set, consult your test set user
guide.
DS-3—If you are testing a clear channel DS-3, you must have a DSX-3 panel or a direct DS-3
interface into the ONS 15327 through the BNC connectors on the MIC. Set the test set for clear
channel DS-3. For information about configuring your test set, consult your test set user guide.
Step
11.
NTP-B173 Point-to-Point Network Acceptance Test
"DLP-B60 Log into CTC" task on page 2-23
"NTP-B181 Create an Automatically Routed DS-1 Circuit"
"NTP-B184 Create an Automatically Routed DS-3 Circuit"
Cisco ONS 15327 Procedure Guide, R4.0
for instructions.
to export the alarm data to a file.
to export the condition data to a file.
for
4-7