Chapter 4
Turn Up Network

NTP-B175 BLSR Acceptance Test

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Note
This procedure requires that you create test circuits and perform span switches around the ring. For
clarity, "Node 1" refers to the login node where you begin the procedure. "Node 2" refers to the node
connected to the east OC-N trunk (span) card of Node 1, "Node 3" refers to the node connected to the
east OC-N trunk card of Node 2, and so on.
Log into one of the ONS 15327s on the BLSR you are testing. (This node will be called Node 1.) See
Step 1
the
with Step 2.
From the View menu choose Go to Network View.
Step 2
Click the Alarms tab.
Step 3
a.
b.
Complete the
Step 4
drive.
Click the Conditions tab. Verify that the network does not have any unexplained conditions. If
Step 5
unexplained conditions are present, resolve them before continuing. Refer to the Cisco ONS 15327
Troubleshooting Guide.
Complete the
Step 6
hard drive.
On the network view, double-click Node 1.
Step 7
Complete the
Step 8
Create a test circuit from Node 1 to the node connected to the east OC-N trunk card of Node 1. (This
Step 9
node will be called Node 2.)
March 2003
This procedure tests a two-fiber BLSR.
Test set and cables appropriate for the test circuit
NTP-B40 Provision BLSR Nodes, page 4-14
NTP-B126 Create a BLSR, page 4-15
As needed
Onsite
Provisioning or higher
"DLP-B60 Log into CTC" task on page 2-23
Verify that the network does not have any unexplained alarms. If unexplained alarms are present,
resolve them before continuing. Refer to the Cisco ONS 15327 Troubleshooting Guide.
Ensure that the alarm filter icon in the lower right corner is not indented. If so, click it once to turn
it off. When you are done checking for alarms, click the icon again to turn alarm filtering back on.
See the
"DLP-B227 Disable Alarm Filtering" task on page 6-30
"DLP-B139 Export CTC Data" task on page 6-3
"DLP-B139 Export CTC Data" task on page 6-3
"DLP-B217 BLSR Exercise Ring Test" task on page
For DS-1 circuits, complete the
procedure on page
5-5. When you set the circuit state, choose IS and check the Apply to drop ports
check box.
For DS-3 circuits, complete the
procedure on page
5-18. When you set the circuit state, choose IS and check the Apply to drop
ports check box.
for instructions. If you are already logged in, continue
to export alarm data to a file on your hard
"NTP-B181 Create an Automatically Routed DS-1 Circuit"
"NTP-B184 Create an Automatically Routed DS-3 Circuit"
Cisco ONS 15327 Procedure Guide, R4.0
NTP-B175 BLSR Acceptance Test
for instructions.
to export condition data to a file on your
4-19.