NTP-B195 Monitor Electrical or Optical Performance

DLP-B261 Refresh PM Counts for a Different Port

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, double-click an XTC card (for electrical PM counts) or OC-N card. The card view appears.
Step 1
Step 2
Click the Performance tab.
From the Port drop-down menu choose the desired port to highlight your selection.
Step 3
Click the Refresh button. The PM counts for the newly selected port appear.
Step 4
Return to your originating procedure (NTP).
Step 5

DLP-B124 Refresh Electrical or Optical PM Counts at Fifteen-Minute Intervals

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, double-click an XTC card (for electrical PM counts) or OC-N card. The card view appears.
Step 1
Click the Performance tab.
Step 2
Click the 15 min radio button.
Step 3
Click the Refresh button. Performance monitoring parameters appear in 15-minute intervals
Step 4
synchronized with the time of day.
View the Curr column to find PM counts for the current 15-minute interval.
Step 5
Each monitored performance parameter has corresponding threshold values for the current time period.
If the value of the counter exceeds the threshold value for a particular 15-minute interval, a threshold
crossing alert (TCA) is raised. The PM number represents the counter value for each specific
performance monitoring parameter.
Cisco ONS 15327 Procedure Guide, R4.0
7-8
This task changes the window view to display PM counts for another
port on a multiport card.
None
DLP-B60 Log into CTC, page 2-23
As needed
Onsite or remote
Retrieve or higher
This task changes the window view to display PM counts in 15-minute
intervals.
None
DLP-B60 Log into CTC, page 2-23
As needed
Onsite or remote
Retrieve or higher