Dlp-B222 Provision G-Series Ethernet Ports - Cisco ONS 15327 Procedure Manual

Hide thumbs Also See for ONS 15327:
Table of Contents

Advertisement

Chapter 5
Create Circuits and VT Tunnels
Complete the
Step 13
complete the
port-mapped mode circuit.
Stop. You have completed this procedure.

DLP-B222 Provision G-Series Ethernet Ports

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In the node view, double-click the G-Series card graphic to open the card.
Step 1
Click the Provisioning > Port tabs.
Step 2
For each G-Series port, provision the following parameters:
Step 3
Note
Note
Click Apply.
Step 4
Refresh the Ethernet statistics:
Step 5
a.
b.
Note
March 2003
NTP-B148 Create a Manual Cross-Connect for a G-Series or an E-Series in Port-Mapped Mode
"NTP-B149 Test G-Series Circuits" procedure on page 5-78
"NTP-B146 Test E-Series Circuits" procedure on page 5-72
This task provisions G-Series Ethernet ports.
None
DLP-B60 Log into CTC, page 2-23
Required to enable Ethernet traffic on the G-Series
Onsite or remote
Provisioning or higher
Port Name—If you want to label the port, type the port name.
State—Choose IS to put the port in service.
Flow Control Neg—Click this check box to enable flow control negotiation on the port. If you do
not want to enable flow control, uncheck the box.
To activate flow control, the Ethernet device attached to the G-Series card must be set to
auto-negotiation. If flow control is enabled but the negotiation status indicates no flow control,
check the auto-negotiation settings on the attached Ethernet device.
Max Size—To permit the acceptance of jumbo size Ethernet frames, choose Jumbo. If you do not
want to permit jumbo size Ethernet frames, choose 1548.
The maximum frame size of 1548 bytes enables the port to accept valid Ethernet frames that use
protocols, such as Inter-Switch Link (ISL). ISL adds 30 bytes of overhead and may cause the
frame size to exceed the traditional 1518 byte maximum.
Click the Performance > Statistics tabs.
Click the Refresh button.
Reprovisioning an Ethernet port on the G-Series card does not reset the Ethernet statistics for
that port.
for the G-Series circuit, or
for the E-Series in
Cisco ONS 15327 Procedure Guide, R4.0