DLP-B318 Refresh Electrical or Optical PM Counts at One-Day Intervals

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Step 1
In node view, double-click an XTC card (for electrical PM counts) or OC-N card. The card view appears.
Step 2
Click the Performance tab.
Step 3
Click the 1 day radio button.
Click Refresh. Performance monitoring appears in 1-day intervals synchronized with the time of day.
Step 4
View the Curr column to find PM counts for the current 1-day interval.
Step 5
Each monitored performance parameter has corresponding threshold values for the current time period.
If the value of the counter exceeds the threshold value for a particular 1-day interval, a threshold crossing
alert (TCA) is raised. The PM number represents the counter value for each performance monitoring
parameter.
View the Prev-n columns to find PM counts for the previous 1-day intervals.
Step 6
Note
Step 7
Return to your originating procedure (NTP).
March 2003
If a complete 15-minute interval count is not possible, the value appears with a yellow
background. An incomplete or incorrect count can be caused by monitoring for less than 15
minutes after the counter started, changing node timing settings, changing the time zone settings,
replacing a card, resetting a card, or by changing port states. When the problem is corrected, the
subsequent 15-minute interval appears with a white background.
This task changes the window to display PM parameters in 1-day
intervals.
None
DLP-B60 Log into CTC, page 2-23
As needed
Onsite or remote
Retrieve or higher
If a complete count over a 1-day interval is not possible, the value appears with a yellow
background. An incomplete or incorrect count can be caused by monitoring for less than 24
hours after the counter started, changing node timing settings, changing the time zone settings,
replacing a card, resetting a card, or by changing port states. When the problem is corrected, the
subsequent 1-day interval appears with a white background.
NTP-B195 Monitor Electrical or Optical Performance
Cisco ONS 15327 Procedure Guide, R4.0
7-9