[ESC+WD] Partial Copy

Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Copying specified area to another place.
[Format]
<WD>VaaaaaHbbbbYcccccXdddd
Parameter
a [Vertical start point of original data] = Valid range: Refer to the table below.
b [Horizontal start point of original data] = Valid range: Refer to the table below.
c [Vertical dot size of original data] = Valid range: Refer to the table below.
d [Horizontal dot size of original data] = Valid range: Refer to the table below.
[Coding Example]
Vertical start point of original data: 50, Horizontal start point of original data: 50,
Vertical dot size of original data: 200, Horizontal dot size of original data: 400
<A>
<V>50<H>50<P>2<L>0202<XU>ABCD
<V>300<H>100<WD>V50H50Y200X400
<Q>2
<Z>
dddd
aaaaa
bbbb
A A B B C C D D
ccccc
Dotted line part indicates the copied area.
Actual print portion is "ABCD".
[Supplementary Explanation]
To locate the destination of copy, specify Vertical Print Position <V> and Horizontal Print
Position <H> prior to this command.
Destination of copy has to be outside of specified original data.
ESC
<1B>
16
Nil
When the power is OFF
Valid range within items
Valid range between items
A A B B C C D D
58
WD
<57>
<44>
16
16
The set parameter is not maintained.
The set command becomes invalid.
The set parameter becomes invalid.
Parameter
VaaaaaHbbbbYcccccXdddd