[ESC+BC] CODE 93 Barcode
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying CODE93 barcode.
[Format]
<BC>aabbbccn...n
•
Parameter
a [Narrow bar] = Valid Range : 01 to 36 dots
b [Height of Barcode] = Valid Range : 001 to 999 dots
c [Digit No. of data] = Valid Range : 01 to 99
n [Print data] = Barcode data(Refer to the CODE93 – Code Table.)
[Coding Example]
Narrow bar width: 02, Barcode height: 120, Number of digit: 12, Print data: ABCD123456xy
<A>
<V>100<H>200<BC>0212012ABCD123456xy
<Q>2
<Z>
[Supplementary Explanation]
•
C/D is an auto-generation.
•
Start code and stop code will be automatically added.
•
Maximum entry digit number of data is 99.
•
[Digit No. of data] and No. of input data have to be equal.
•
Command error will occur when No. of input data and [Digit No. of data] are not matched.
ESC
<1B>
16
Nil
When the power is OFF
Valid range within items
Valid range between items
197
BC
<42>
<43>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Parameter