[ESC+YS] Format Registration
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Registering print format.
[Format]
<YS>,aaa
•
Parameter
a [Format registration number] = Valid Range : 1 to 999
[Coding Example]
<A>
<CC>1
<YS>,1
</N>,3,3
<%>0<V>100<H>200<P>2<L>0101<XM>ABC
<Z>
[Supplementary Explanation]
•
When registering multiple formats, Delimit Start of Data Transmission <A> and End of Data
Transmission <Z> with one format.
•
Specify Card Slot for Use <CC> prior to this command <YS> by all means.
•
Use this command and Registration of Field </N> as a pair.
•
Attempts to re-register with registered No., error will occur, and the targeted content will be
printed.
•
The error occurs when specifying unused or specifying the slot which the printer is allocated.
[Note]
•
Do not turn the printer's power off when accessing to the memory. When the printer power is off
while memory accessing, the data in the accessed media may be corrupted.
•
The maximum registration with </N> is 99 fields. (Refer to the customizable print command of
the field registration (ESC+/N) for the commands can be registered.)
•
The maximum registration with other than </N> is 50 fields. Refer to the customizable print
command for the commands can be registered.)
ESC
<1B>
16
Nil
When the power is OFF
Valid range within items
Valid range between items
380
YS
<59>
<53>
16
16
The set parameter is not maintained.
The set parameter is valid until the next valid setting.
The set parameter is valid until the next valid setting.
Parameter
,aaa