[ESC+RU] EPC/TID return (UHF M6e) (CL4NX Only)

Command
Hexadecimal code
Initial Value
Valid range and term of
command
[Function]
This command is used to return EPC/TID together with the result when data is written to the RFID
tag by the <IP0> command.
[Format]
Return specification : <RU>,aa
Request to return : [DC2]PK
Parameters
Symbol
aa
Identifier
[[DC2]PK return data format (normal)]
[STX]a...a,b,c,d...d[CR][LF][ETX]
[Return data]
Symbol
a
b
c
d
ESC
<1B>
16
aa=00
When turning off the power
Valid range within item
Valid range between items
Parameter name
Parameter name
Total number of data byte
* This is the total number of bytes after parameter b.
The delimiting comma between parameters a and b,
and the ETX are not included.
Write result status
Error symbol
EPC/TID return data
RU
<52>
<55>
16
16
The set command is not maintained.
The set parameter is valid until the next valid setting.
The set parameter is valid until the next valid setting.
00: Not returned (default
setting)
01: Validate return
Obtain return data by
sending [DC2]PK
432
Parameter
,aa
Valid range
Two character fixation
Valid range
Data size from the first write result
status until before [ETX]
Maximum 5 digits
0: Write failure
1: Write success
* Specified in text format
N: No error
E: EPC write error
T: TID read error
A: All errors
* Specified in text format
Refer to "EPC/TID return data"
below.