[Dc2+Pk] Uid Return Request (Iso/Iec15693) (Cl4Nx Only) - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

[DC2+PK] UID return request (ISO/IEC15693) (CL4NX Only)

Command
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Returns the status of RFID tag write by <RK> command and UID.
[Format]
[DC2]PK
[[DC2]PK return data format (normal)]
[STX]a...a,b,c,d...d[CR][LF][ETX]
[Return data]
Symbol
a
Total number of data byte
* This is the total number of bytes after
parameter b. The delimiting comma between
parameters a and b, and the ETX are not
included.
b
Write result status
c
Error symbol
d
UID return data
[Format of UID return data]
"Specify memory" + ":"+"Data" + "Line feed(0DH,0AH)"
ee:f...f[CR][LF]
DC2
<12>
16
None
When turning off the power
Valid range
Printer operation in
progress
Error
Parameter name
575
PK
<50>
<4B>
16
16
-
-
The command cannot be received during the printer
operation. ([NAK] return)
Commands can be received even if an error is occurring.
Data size from the first write result status until
before [ETX]
Maximum 5 digits
0: Write failure
1: Write success
* Specified in text format.
N: No error
U: UID read error
A: All errors
* Specified in text format.
Refer to [UID return data] as below.
* Specified in text format.
Parameter
None
Valid range

Hide quick links: