7.15 Modification
7.15

ESC+WD Partial Copy

Partial Copy
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Copying specified area to another place.
[Format]
<WD>VaaaaaHbbbbYcccccXdddd
●Parameter
a[Vertical start point of original data]
b[Horizontal start point of original data] = Valid range: See the table below.
c[Vertical dot size of original data]
d[Horizontal dot size of original data]
[Coding Example]
Vertical start point of original data: 50
Vertical dot size of original data: 200
<A>
<V>50<H>50<P>2<L>0202<XM>ABCD
<V>300<H>100<WD>V50H50Y200X400
<Q>2
<Z>
ccccc
Dotted line part indicates the copied area.
Actual print portion is "ABCD".
[Supplementary Explanation]
1. To locate the destination of copy, specify Vertical Print Position <V> and Horizontal Print Position <H> prior to this
command.
2. Destination of copy has to be outside of specified original data.
3. When the print start position of the copied area is outside of printable area, printing will not be performed due to
command error.
[Valid Range]
Model
203 dpi
CL4NX
305 dpi
609dpi
203 dpi
CL6NX
305 dpi
(*1) Valid range for "Standard" in "Head Base Position" setting.
(*2) Valid range for "Left-justify" in "Head Base Position" setting.
* Even if the specified parameter is within a valid range, it may get out of the valid range depending on its print start
position, base position of copy or dot size. In that case, command error will occur.
Refer to the operator manual for further information of the setting.
WD
<57>
<44>
16
16
= Valid range: See the table below.
= Valid range: See the table below.
= Valid range: See the table below.
dddd
aaaaa
bbbb
ABCD
ABCD
Horizontal start point of original data
Horizontal dot size of original data
1 to 832
1 to 1248
1 to 2496
1 to 1216 (*1)
1 to 1340 (*2)
1 to 1984 (*1)
1 to 2010 (*2)
33
ESC+WD
Parameter
VaaaaaHbbbbYcccccXdddd
The set parameter is not maintained.
The set command becomes invalid.
The set parameter becomes invalid.
Horizontal start point of original data: 50
Horizontal dot size of original data: 400
Valid range (dots)
Vertical start point of original data
Vertical dot size of original data
1 to 20000
1 to 18000
1 to 9600
1 to 20000
1 to 18000