[ESC+RK] RFID write (ISO/IEC14443 TypeA) (CL4NX Only)

Command
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifies the data to write on RFID tag that supports ISO/IEC14443 Type A.
[Format]
[When setting NFC(NDEF) format user data]
<RK>a(,b),NFC:x(,ict:xx)(,lck:xxxx)(,dlk:yyyyyy)(,spl:x)(,ptl:xx)(,ecd:x)(,lgc:aaaaa...aaaa)
(,idt:xxx...xxx)(,ndd:mmmm,nnnnn...nnnn)(,hma:xxxxxxxxxxxx)(,dnm:aaaaa...aaaa)(,dcl:xxxxxx)
(,scl:xxxx)(,ver:x,x)(,rfb:x)(,ssi:xxx,aaa...aaa)(,nky:xxx,aaa...aaa)(,atp:xxxx)(,etp:xxxx)(,amc:e)
(,ams:hhh)(,amb:f)(,ame:g)(,nce:l)(,cfl:o)(,lma:ii)(,prt:j)(,acl:k)(,lim:p)(,apw:ssssssss)(pck:tttt)
(,psw:ssssssss)(,sa0:uu)(,sa1:vv)(,sak:wwwww...wwww)(,aky:wwwww...wwww)(,fsw:r)
[When setting free format user data / when there is no user data]
<RK>a(,b),Dmmmm,n ~ n(,NFC:f)(,ict:xx)(,wsb:sss)(,lck:xxxx)(,dlk:yyyyyy)(,amc:e)(,ams:hhh)
(,amb:f)(,ame:g)(,cfl:o)(,lma:iii)(,prt:j)(,acl:k)(,lim:p)(,apw:ssssssss)(pck:tttt)
(,psw:ssssssss)(,sa0:uu)(,sa1:vv)(,sak:wwwww...wwww)(,aky:wwwww...wwww)(,fsw:r)
Parameter
a
b
Dmmmm
or
dmmmm
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
Specification of inlet type
Valid range for models with module supporting ISO/IEC14443 TypeA: 1
1: NTAG, MIFARE, my-d (supports NFC)
Ignore RFID tag error (omissible)
Valid range: 0 ~ 9
0: Unspecified
This mode stops every time a tag error occurs.
1 ~ 9: Specify how many labels to ignore for RFID tag error
When tag error occurs, retries with next label up to the maximum number of
labels to ignore. This mode will stop the printer when the series of tag errors
exceeds the specified number.
Note:
If this parameter is omitted, the number of retries set under the menu [Interface] >
[RFID] > [Retries] ([DC2]PA's identifier IF, MAX_RETRY_LABEL) is applied instead.
Data input format + number of data to write in bytes
Number of data to write
RK
<52>
<4B>
16
16
The set command will not be maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
This parameter is used when the user data is set by
using free format or when there is no user data.
Specifies the number of bytes for the next parameter
"n:data array to write". This portion should be written