[Esc+Cr] Status 5 Reply Check Setting - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

[ESC+CR] Status 5 reply check setting

Hexadecimal code
Initial value
Valid range and term of
command
[Function]
The BCC check of return and the item number check function are set up of the status 5.
[Format]
<CR>a(,b)
Parameter
a [BCC check]
      0 : BCC check disable (initial value)
      1 : BCC check enable
b
[Item number check] = 0
[Coding Example]
<A>
<ID>****
<CR>1,0
<Z>
[Supplementary Explanation]
[item number check] is a fixed value.
This command cannot be used at the same time the print data.
Use is possible only during status 5 protocol.
Parent topic
Control command
ESC
<1B>
16
a=0
When the power is OFF
Valid range within items
Valid range between items
: Not checked(fixed value)(omissible)
31
CR
<43>
<52>
16
16
The set parameter is maintained.
The set parameter is valid until the next valid setting.
The set command becomes invalid.
Parameter
a(,b)