[Esc+Rk] Rfid Write (Iso/Iec15693) (Cl4Nx Only) - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

[ESC+RK] RFID write (ISO/IEC15693) (CL4NX Only)

Command
Hexadecimal code
Initial Value
Valid range and term of
command
[Function]
Specifies the data to write on RFID tag that supports ISO/IEC15963.
[Format]
[Standard format]
<RK>a,(b,)Dmmmm,n~n(,iso:c)(,wsb:sss)(,lbs:xxx,lbn:yyy)(,eas:v)(,afi:ww)(,dsf:xx)(,eal:g)(,afl:h)
(,dsl:i)(,eap:jjjjjjjj)(,eai:kkkk)(,pw0-4:eeeeeeee)(,aw0-4:ffffffff)(,kpw:gggggggg)(,pps:lll,m)(,fsw:f)
[Conventional format]
<RK>a,(b,)Dmmmm,n~n(,Ws:sss)(,Ls:xxx,Ln:yyy)(,Ea:v)(,Af:ww)(,Ds:xx)(,Al:h)(,Dl:i)(,Fs:f)
 
[Conventional format] is meant for the compatibility with models prior to CL4NX. For CL4NX and
models onwards, create with [Standard format] when using commands as new parameters.
Parameter
a
ESC
<1B>
16
None
When turning off the power
Valid range within item
Valid range between items
Specification of inlet type
Valid range for models with Takaya module: 2,3,5
2 : ICODE
Maximum number of bytes for products are followings;
ICODE SLI : 112
ICODE SLIX : 112
ICODE SLIX-S : 160
3 : Tag-it
Maximum number of bytes for products are followings;
Tag-it HF-I Plus : 256
Tag-it HF-I Pro : 32
Tag-it HF-I Standard : 32
5 : my-d
Maximum number of bytes for products are followings;
my-d vp SRF55V10P(custom) : 1000
my-d vp SRF55V10P(ISO) : 992
Note
A tag error occurs when data exceed the maximum number of bytes for each product.
437
RK
<52>
<4B>
16
16
The set command is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Parameter
See the tables in "・
Parameter" below.