Control Command; [Esc+A] Start Code - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

Control command

Start Code
[ESC+A]
[ESC+Z]
Stop Code
[ESC+Q]
Print Quantity
Job ID Number
[ESC+ID]
[ESC+WK]
Job Name
[ESC+CR]
Status 5 reply check setting
Parent topic
Part 1 SBPL Commands

[ESC+A] Start Code

Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying the start of data transmission.
[Format]
<A>
[Coding Example]
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
[Supplementary Explanation]
Indicates the start of item and to be placed at the head of item.
Use <A> and End of Data Transmission <Z> as a pair of commands.
[Note]
Setting value of all commands excluding a part of system commands will be set to default.
If this command is not specified, printing will not be performed.
Parent topic
Control command
ESC
<1B>
16
Nil
When the power is OFF
Valid range within items
Valid range between items
25
A
<41>
16
The set command is not maintained.
The set command becomes invalid.
The set command becomes invalid.
Parameter
Nil

Hide quick links: