[ESC+GT] BMP File Registration

Hexadecimal code
Initial Value
Valid range and term of
command
[Function]
Specifying the registration of BMP file created by such as Image editing application.
[Format]
<GT>aaa,bbbbb,n...n
Parameter
a [Registration number]
Valid Range : 1 to 999
b [Total bytes of BMP file]
Valid Range : 1 to 99999
Specify the file size of BMP file for total bytes.
n [Data] = BMP file data
Data is sent as binary data (Outputs 8 bits as one character data all at once)
[Coding Example]
<A>
<CC>1
<GT>1,12345,<424D00~00>
<Z>
[Supplementary Explanation]
Specify the card slot number used for Card Slot <CC> prior to this command <GT> by all
means.
Data is sent as binary data (Outputs 8 bits as one character data all at once). In this case, file
size of BMP file becomes the total bytes, and BMP file data becomes data.
When [Total bytes of BMP file] is not matching the transfer data, this may cause malfunction.
Total bytes are the file size displayed at [Property] and such.
BMP file is available in Black/White mode only. In color mode, printing will not be performed due
to command error.
Also, this command is not valid for BMP compressed file. Make sure that the file extension is set
to [BMP] before printing.
The error occurs when unused or the slot which this product is allocated is specified.
[Note]
Do not turn the printer's power off when accessing to the memory. When the printer power is off
while memory accessing, the data in the accessed media may be corrupted.
Parent topic
Memory Card Command
ESC
<1B>
16
Nil
When the power is OFF
Valid range within items
Valid range between items
16
390
GT
<47>
<54>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Parameter
aaa,bbbbb,n...n

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents