SATO CL4NX Programming Reference Manual page 419

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

s:
serial reference
t:
item reference
n:
serial number
g:
Feed without printing
Gen 2 memory bank operation parameters (can be omitted)
u:
User Memory HEX
v:
User Memory ASCII
o:
AFI code
m:
Locking
SSCC96/SGTIN96 conversion parameter
A number from 6 to 12. Number of digits of the
company prefix in the first half of the data specified in
the d parameter.
Number of digits of Serial reference (only when
selecting SSCC96)
Number of digits of the serial reference in the latter
half of the data specified in the d parameter. Specify
a number from 5 to 11, so that when combined with c,
the resultant value is 17.
Number of digits of Item reference (only when
selecting SGTIN96)
Specify a number from 1 to 7, so that when combined
with c, the resultant value is 13.
Serial number 12 digits (fixed) (only when selecting
SGTIN96)
Specify 274877906943 or a smaller number.
Feed control parameters (can be omitted)
Usually, for RFID write item without print data, only
writing of RFID data is performed, and the label is not
fed. (Except for cases where the tag offset is set to
other than default)
When "1" is specified in this parameter, the label is
fed even if the item does not contain print data.
When "0" is specified for this parameter, the label
is not fed for the item without print data, and the
operation is the same as when g: is not specified.
Specify numeric string to write to USER area in
hexadecimals. Specified digits must be multiples of 4.
This can be specified in the range of 4 to 128 digits,
but the maximum number of digits depends on the
used tag.
You may also use the space, tab, line feed in data
separator, but these codes will be skipped.
Specify numeric string to write to USER area in ASCII
data. It is necessary to have data area and data size
information separated with a comma before the data.
For example in specifying a data size as 16, specify
as follows:
V:16,abcd...
Specified digits must be multiples of 2. This can
be specified in the range of 2 to 64 digits, but the
maximum number of digits depends on the used tag.
Application Family Identifier. Specify a hexadecimal
number from 0H to 1FFH. To write as AFI, specify the
ninth bit (MSB) as 1.
5-digit binary number. Set the bit of the bank to be
locked as 1.
If you specify the access code, it results in a
"password lock", and if you omit the access code, it
results in a "permanent lock".
417