[ESC+BM] UPC-A Barcode (With HRI)
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Set the character barcode height of the first and the last digit to the same height of the guard bar.
[Format 1]
<BM>abbcccn...n
•
Parameter
a [barcode type] = H : UPC-A( fixed 'H')
b [Narrow bar] = Valid Range : 01 to 36 dots
c [Height of Barcode] = Valid Range : 001 to 999 dots
n [Print data] = Data : fixed 11 digits
[Coding Example]
Barcode type:UPC-A, Narrow bar width:02, Barcode height :120, Print data: 20123948573
<A>
<H>100<V>100<BM>H0212020123948573
<Q>2
<Z>
ESC
<1B>
16
Nil
When the power is OFF
Valid range within items
Valid range between items
223
BM
<42>
<4D>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Parameter
abbcccn...n