Mode: Readable, Start Position: 30, VOID print: Disabled, (Retry Count: omitted), Host Notification:
Disabled, Specify the number of barcode: Command, (the number of barcode: omitted)
<A>
<VB>1,30,0,,0,0,
<Z>
[Coding Example 3]
Mode: Readable, Start Position: 30, VOID print: Enabled, Retry Count: 3, Host Notification: Disable,
Specify the number of barcode: Setting, the number of barcode: 2
<A>
<VB>1,30,1,3,0,1,2
<Z>
[Coding Example 4]
Mode: Comparison, Start Position: 30, VOID print: Enabled, Retry Count: 3, Host Notification:
Disabled, (Specify the number of barcode: omitted), (the number of barcode: omitted)
<A>
<VB>2,30,1,3,0,,
<Z>
[Supplementary Explanation]
•
Each parameter can be omitted.
•
When RFID function is enabled, this command returns a command error.
•
This command is not allowed to be used with other commands (it cannot be used in the printing
item).
Parent topic
System Command
365