[ESC+%] Rotation
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying the counter-clockwise rotation of font and barcode.
[Format]
<%>a
•
Parameter
a [Rotative direction]
0: Parallel 1 (0 degree)
1: Serial 1 (90-degree)
2: Parallel 2 (180-degree)
3: Serial 2 (270-degree)
[Coding Example]
Font rotation: Parallel 2 (180-degree), Barcode rotation: Serial 1 (90-degree)
<A>
<%>2
<V>100<H>400<P>3<L>0403<XM>ABCD
<%>1
<V>400<H>200<BD>103160*123*
<Q>2
<Z>
[Supplementary Explanation]
•
Position specification of Vertical Print Position <V> and Horizontal Print Position <H> are the
absolute value from its base reference point.
•
When the value of parameter "a" is between 4 and 9, it will be processed as a command error
and ignored. When the value other than numeric is specified, this will be ignored and printing
will be performed at 0 degree.
•
Print of barcode using Serial 1 or Serial 2 may cause blur. Drop the print speed for rotation print
of Serial 1 and Serial 2 for better performance.
ESC
<1B>
16
a=0
When the power is OFF
Valid range within items
Valid range between items
40
%
<25>
16
The set parameter is not maintained.
The set parameter is valid until the next valid setting.
The set parameter becomes initial value at the next item
<A>.
Parameter
a