[ESC+BV] MaxiCode (Compatible command)
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying MaxiCode.
[Format]
<BV>a,b,c,ddddddddd,eee,fff,n...n
•
Parameter
a [Symbol number] = Valid Range : 1 to 8
b [Number of symbol digit] = Valid Range : 1 to 8
c [Mode]
2 : Transportation only
3 : Transportation only
4 : Standard symbol
6 : Reader programing
d [Postal code] = Valid Range : 0 to 999999999 (Mode 2)
* Mode 2: Max 9 digits (Numeric only)
* Mode 3: Fixed 6 digits (Capital alphabet)
e [Country code] = Valid Range : 001 to 999
f [Service class] = Valid Range : 001 to 999
n [Low priority message] = Alphanumeric/Symbol
Mode
Service class
2
Fixed 3 digits
(Numeric only)
3
4
Omission
6
[Coding Example]
<A>
<V>100<H>200<BV>1,1,2,123456789,001,002,SAHTHA
<Q>2
<Z>
ESC
<1B>
16
Nil
When the power is OFF
Valid range within items
Valid range between
items
000000 to 999999 (Mode 3)
Country code
Fixed 3 digits
Max. 9 digits
(Numeric only)
Fixed 6 digits
(Alphanumeric)
309
BV
Parameter
<42>
<56>
a,b,c,ddddddddd,eee,fff,n...n
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Postal code
Numeric only
123
138
Maximum print data
Alphanumeric
84
93