SATO CL4NX Programming Reference Manual page 524

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

Symbol
c(f...)
Data size of setting information
* The size of setting information is equivalent
d(g...)
Setting data
* text format
* Items that need to be encrypted to perform
[Setting data format]
"Name of setting item" + ":" + "Setting data" + "Line feed(0DH, 0AH)"
h...h:i...i[CR][LF](j...j:k...k[CR][LF])...
[Setting data]
Symbol
h(j ...)
i(k ...)
Data sample)
SPEED:4
LEVEL:5
[Return data format (normal)]
[ACK]<06>
16
[Return data format (when a command error occurs)]
[NAK]<15>
16
[Exception processing]
Parameter name
Total number of data in bytes
Identifier
Data size of settings in bytes
Setting item
Setting data
Parameter name
to the bytes by section from parameter d.
The comma in between the sections is not
included.
encryption
Parameter
name
Setting item
See Settings Table
Setting data
See Settings Table
Command Error
Invalid identifier (skip)
Command Error
Invalid setting item (skip)
Invalid setting item (skip)
Valid range
SI: SIPL settings
SD: SDPL settings
ST: STCL settings
SA: AEP settings
SE: SEPL settings
0 to 524277
Refer to the table of
[Setting data] below.
Valid range
Exception condition
A value outside the
range is specified
522
Acquisition method
Acquire until ","
Data sized of setting
information
Acquisition method
Valid until ":"
Valid until "[CR][LF]"
The specified size and
received size are different
*1 *2
Command Error
Command Error
*3
Command Error

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents