[Supplemental explanation]
The result of writing and EPC/TID is returned when [DC2]PK is received after RFID writing has
been performed.
Although write is successful status will be returned without data if you fail to read EPC/TID since
EPC/TIC read will be done separately from write.
Return data remains the same when EPC code write is specified without print data. Previous
value will be returned.
<RU>,01 return sequence (for a Gen2 tag having the TID of E200680612345678)
<RU>,01 *1
Return based on [DC2]PK
<IP0>e:h,epc:E0123456789ABCDEF0123456;
Write command
[DC2]PK
*1 Most common commands such as <A>, <Z> are not described in the above diagram.
*2 The content of the return UID/EPC is an example. The actual value varies depending on the tag.
[Supplemental explanation]
Keep the EPC/TID data to be returned within 256 characters.
The printer operation corresponding to the <IPO> command is performed in the order of writing
the data to the tag, and then performing EPC/TID reading.
Host
Printer
The settings of return based on [DC2]PK are retained
Enabled until power is turned OFF
Acquire TID immediately after successful write, and
store it in the memory with the success status.
Return the write status (write success) and TID data
[STX]25,1,N,ID:E200680612345678 [CR][LF][ETX]
*2