[ESC+TK] Forced Tear Off

Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Executes Tear off compulsory.
[Format]
<TK>
[Coding Example]
<A>
<TK>
<Z>
[Supplementary Explanation]
This command can be specified only in Tear off mode.
With this command, the printer executes Tear off motion without waiting the time set by
command <ESC+TW>. If the next data is received before Tear off motion, Tear off is executed
compulsory.
This command cannot be used in combination with other commands. Please send the
command independently.
[Notes]
This command can be used to shorten print time set at Option Waiting Time, if it is sure that
there is no following item.
Parent topic
System Command
ESC
<1B>
16
Nil
When the power is OFF
Valid range within items
Valid range between items
361
TK
<54>
<4B>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Parameter