Return status of Status 4

This communication protocol is used to return the condition of this product and reply as a status to
the host by receiving four types of request commands and print commands.
The following describes about commands and return status.
1) Status request command
This command returns the job ID number of receiving data in printing, the status of this product,
the number of remaining label to print, and job name to host. All "0" (HEX 30H) is returned for print
quality when the print is completed or when there is no received data. A "space" (HEX 20H) is
returned for the job ID when Job ID Number <ID> is not specified.
Please do not send ENQ (Status request) while sending print data (STX <A> to <Z> ETX). Status
would not be returned properly or print would not be performed properly if ENQ is sent.
1. Command ENQ (HEX 05H)
2. Return status, Format
Number of
transmission bytes
4 bytes
00000020H
Number of
transmission bytes
4 bytes
0000001CH
3. Return status list
OFFLINE
STATE
ONLINE
STATE
Number of
ENQ
transmission bytes
1 byte
4 bytes
0000001CH
05H
ENQ
STX
ID No.
1 byte
1 byte
2 bytes
05H
02H
The ID no. specified with Job ID
specification command is set.
STX
ID no.
1 byte
2 bytes
02H
Description
NO ERROR
RIBBON/LABEL NEAR END
BUFFER NEAR FULL
RIBBON/LABEL NEAR END & BUFFER NEAR FULL
PRINT HALT (NO ERROR)
(UNUSED) BATTERY NEAR END
(UNUSED) BATTERY NEAR END & RIBBON NEAR END
(UNUSED) BATTERY NEAR END & BUFFER NEAR FULL
(UNUSED) BATTERY NEAR END & RIBBON NEAR END &
BUFFER NEAR FULL
WAIT TO
NO ERROR
RECEIVE
RIBBON/LABEL NEAR END
STX
ID No.
Status
1 byte
2 bytes
1 byte
02H
No. of
Status
JOBname
Remaining
1 byte
16 bytes
labels
6 bytes
000000 through 999999
Status
Remaining no.
JOB name
1 byte
16 bytes
of labels
6 bytes
627
LAN, Wireless LAN 36 bytes LAN
Legacy Status setting is valid.
No. of
JOB name
ETX
Remaining
16 bytes
1 byte
labels
03H
6 bytes
ETX
LAN, WLAN
1 byte
32 bytes
Legacy Status for Port9100 Disable
03H
The print job name specified with JOB
name specification command is set.
ETX
Interface other than
the above
1 byte
03H
27 bytes
ASCII
0
1
2
3
4
5
6
7
8
A
B
HEX
30
31
32
33
34
35
36
37
38
41
42