[ESC+RU] IDm return (FeliCa) (CL4NX Only)

Command
Hexadecimal code
Initial Value
Valid range and term of
command
[Function]
Returns the result of RFID tag write using <RK> command together with a 64-digit hexadecimal
numeric sequence as a result of IDm+PMm+ID block.
[Format]
Return specification: <RU>,aa
Request to return: [DC2]PK
Parameters
Symbol
aa
Identifier
[[DC2]PK return data format (normal)]
[STX]a...a,b,c,d...d[CR][LF][ETX]
[Return data]
Symbol
a
b
c
d
ESC
<1B>
16
00
When turning off the power
Valid range within item
Valid range between items
Parameter name
Parameter name
Total number of data byte
* This is the total number of bytes after parameter b. The
delimiting comma between parameters a and b, and the
ETX are not included.
Write result status
Error symbol
IDm return data
RU
<52>
<55>
16
16
The set command is not maintained.
The set parameter is in effect until a new specification is
made.
The set parameter is in effect until a new specification is
made.
00: Not returned (default
setting)
01: Validate return
Obtain return data by
sending [DC2]PK.
508
Parameter
,aa
Valid range
Two character fixation
Valid range
Data size from the first write result
status until before [ETX]
Maximum 5 digits
0: Write failure
1: Write success
Note: Specified in text format.
N: No error
I: IDm read error
A: All errors
Note: Specified in text format.
Refer to "IDm return data" as
below.