[Esc+#] Base Reference Point (Cl4Nx Only) - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

[ESC+#] Base Reference Point (CL4NX Only)

Hexadecimal code
初期値
Valid range and term of
command
[Function]
Specify the base reference point in vertical direction.
[Format]
<#>abbb
Parameter
a [Moving Direction]
+: Feed Direction
-: Reverse Direction
b [Distance in dots]
Valid range: 000 to 600 (in dots)
[Coding Example]
<A>
<#>+040
<Z>
#+040
#000
#-040
[Supplementary Explanation]
Initial value of the reference position is 0 dot.
The position specified with < # > command is a start position that measures Y value described in
"CL4NX Inlay Configuration Guide".
When parameter "a" [Moving direction] = "-: Reverse Direction" , do not specify 58 mm or more
in total with other offset adjustment value. If it is set to 58 mm or more, it does not stop properly.
Parent topic
System Command
ESC
<1B>
16
なし
When the power is OFF
Valid range within items
Valid range between items
366
#
<23>
16
The set parameter is maintained.
The set parameter is valid until next specification is
made.
The set parameter is valid until next specification is
made.
Parameter
abbb
Print reference position
Cut reference position

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx