[ESC+WK] Job Name
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying job name for status return.
[Format]
<WK>aaaaaaaaaaaaaaaa
•
Parameter
a [Job Name] = ASCII code 16-digit, Shift JIS Kanji 8-digit
[Coding Example]
Job name: SATO
<A>
<ID>01
<WK>SATO
<V>200<H>100<P>0<$>B,100,100,6
<$=>SATOPRINTER
<Q>2
<Z>
[Supplementary Explanation]
•
When Status 4 is used for interface protocol, specified job name can be set to the telegraphic
status.
•
Status can be confirmed sending status request (ENQ).
•
Include this command within items and use between start code <A> and stop code <Z>.
•
This command can be used in combination with Job ID Number <ID>.
[Note]
•
In status return interface protocol, this command becomes valid when status request (ENQ) is
received while printing (QTY≠0, includes at the time of Offline and Error).
•
In status return communication protocol, if status request (ENQ) is received when printing is not
in progress (QTY=0, No received data when power is ON), space (20H) will be set to status and
returned.
•
When Job ID Number <ID> is used more than twice within the items of <A> and <Z>, the last
specified value becomes valid.
•
For more information, refer to the "Interface Specifications".
Parent topic
Control command
ESC
WK
<1B>
<57>
16
aaaaaaaaaaaaaaaa=<20>
When the power is OFF
Valid range within items
Valid range between items
Parameter
<4B>
aaaaaaaaaaaaaaaa
16
16
16
The set parameter is not maintained.
The set parameter is valid until the next valid setting.
The set command becomes invalid.
30