Parameters from here can be specified in any order.
Parameters related to specifying block to start writing (omissible)
wsb:
Specify block to start writing
(former Ws:)
Mapping table of inlet type and number of blocks, and total capacity
Inlet Type
ICODE(a=2)
ICODE SLI
ICODE SLIX
ICODE SLIX-S
Tag-it(a=3)
Tag-it HF-I Plus
Tag-it HF-I Pro
Tag-it HF-I
Standard
my-d(a=5)
my-d vp
SRF55V10P
(Custom)
my-d vp
SRF55V10P
(ISO)
lbs:
Block to start locking
(former Ls:)
lbn:
Number of blocks to lock
(former Ln:)
Allows to lock specified blocks (making it read-only).
Specify the block to start locking with "lbs:" and specify the number of blocks to lock with "lbn:".
1 is assigned to "lbn:" if only "lbs:" was specified without specifying "lbn:".
0 is assigned to "lbs:" if only "lbn" was specified without specifying "lbs".
The block will not be locked if 0 was specified to "lbn:" or both of the parameters were omitted.
Note that once locked, the block area becomes read-only and cannot be reset.
In applying lock for my-d, specify 1 for "iso:" and access with ISO-15693 standard.
Multiple Block Locks
Supports locking of multiple blocks, up to 16 positions may be locked, and a parameter error will occur if that
number is exceeded. Blocks should be specified with the following pair of parameters: (,lbs:xxx,lbn:yyy). A
Product
Capacity
of 1 block.
4bytes
4bytes
4bytes
4bytes
4bytes
4bytes
8bytes
4bytes
Parameters for Block Lock (omissible)
440
Specifies the block to start writing the data. The 0th
block is specified if omitted.
Block is a unit to write to user memory. The following
values in the table are allowed based on the type of
inlets.
A maximum up to a 3-digit decimal can be specified,
but a parameter error occurs if it exceeds the
maximum amount for the specified inlet. Please see
the following table.
Note that the memory address relation is inverted
between when accessing to my-d with iso:0 (custom)
and with iso:1 (ISO) thus the capacity of one block
and total capacity change.
The number of the
overall blocks.
28blocks
28blocks
40blocks
64blocks
8blocks
8blocks
125blocks
248blocks
Available to specify up to 3 digits in decimals.
A parameter error occurs when it exceeds the
maximum for the specified inlet.
Available to specify up to 3 digits in decimals.
A parameter error occurs when it exceeds the
maximum for the specified inlet.
Total capacity.
112bytes
112bytes
160bytes
256bytes
32bytes
32bytes
1000bytes
992bytes