[ESC+PO] Offset
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Gives offset to media's stop position on the fly.
[Format]
<PO>abcc
•
Parameter
a [Offset]
0 : Cutter
1 : Dispenser
2 : Tear-off
3 : Continuous
b [Offset direction]
+ : Feed forward
- : Backward
c [Amount of offset] = Valid range : 00 to 99 (dot)
[Coding Example]
<A>
<PO>3+08
<Z>
[Supplementary Explanation]
•
This command does not need to be set in normal printing.
•
Please specify an appropriate value when the printing is off, which is unique for each printer.
Printer will not work properly if you do not specify appropriate value.
Parent topic
System Command
ESC
<1B>
16
a=0, b=+, cc=00
When the power is OFF
Valid range within items
Valid range between items
352
PO
<50>
<4F>
16
16
The set parameter is not maintained.
The set parameter is valid until the next valid setting.
The set parameter is valid until the next valid setting.
Parameter
abcc