cfl:
NFC counter password restriction
Parameters related to configuration for authentication (omissible)
lma:
Set address for password-lock
prt:
Set protection format
acl:
Lock authentication configuration
information
Parameters related to NFC counter (omissible)
472
1: enabled (automatically updates counter when
READ command is executed)
0: disabled
CFG1:ACCESS:NFC_CNT_PWD_PROT
Sets availability of NFC counter password restriction.
Valid range: 0 or 1
0: disabled (password not valid)
1: enabled (password is valid)
Sets the address to the block that requires password
check.
Valid range: 0-255, 3-digit decimal
A parameter error will occur if a value exceeding
specified inlet capacity is specified.
IC Chip type
Product
00
NTAG203
01
NTAG210
03
NTAG213
04
NTAG215
05
NTAG216
30
MIFARE
Ultralight
31
MIFARE
Ultralight (EV1)
(MF0UL11)
33
MIFARE
Ultralight C
62
my-d move
NFC
-: No password
*: my-d move NFC is excluded because it is applied
to a fixed area.
Sets the type of restriction.
Valid range: 0 or 1
0: write protect
1: read-write protect
Note: When designated for my-d move NFC, regardless of
set value this setting:
(1) Cannot be canceled.
(2) "dlk" cannot be used.
Locks authentication configuration except for
password.
Valid range: 0 or 1
Unlockable after locking.
Valid address
-
0 to 11
0 to 35
0 to 123
0 to 221
-