Basic Specification - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

RS-232C

Basic specification

READY/BUSY
XON/XOFF
Status5 return
Status4 return
Status3 return
Caution
Parent topic
Part 2 Interface Specification
Basic specification
This interface complies with the RS-232C standard.
Various communication settings are available by the interface mode of the printer or the printer setup
tool.
Interface
D-sub 9pin Female
Communication settings
Setting range in the communication settings mode
Item
Data bit length
Parity bit
Stop bit
Baud rate
Protocol
BCC check for Status 5
Synchronization method
Asynchronous method
Maximum receive buffer capacity
2.95 MB
0 M B
N ear full occures
Near full release
Code
ASCII (7bit) Graphic (8 bit)
Configuration
7, 8 (bit)
NONE, ODD, EVEN
1, 2 (bit)
2400, 4800, 9600, 19200, 38400, 57600, 115200 (bps)
READY/BUSY, XON/XOFF, Status 2, Status 3, Status 4, Status
5
Refer to Communication protocol for details.
Enable / Disable
0.95 MB rem ains
1. 95 M B re mai ns
649
2.95 MB
Default
8 bit
NONE
1 bit
115200 bps
Status 4
Disable

Hide quick links: