SATO CL4NX Programming Reference Manual page 193

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

[Supplementary Explanation]
The inter-character pitch of the barcode is valid at CODABAR (NW-7), CODE39, Industrial 2of5
and Matrix 2of5. The barcode inter-character pitch is set by specifying the character pitch <P>
immediately before.
If not set, the inter-character pitch will be of the same size as a narrow space width.
Command
<BD>
For print data of each barcode type, refer to the code tables of barcode.
The barcode translation of following codes will be restricted to conditions below: JAN/EAN8,
JAN/EAN13, UPC-A
For 203 dpi (8 dots/mm) : Narrow bar width must be [02], [03]
For 305 dpi (12 dots/mm) : Narrow bar width must be [03], [04]
For 609 dpi (24 dots/mm) : Narrow bar width must be [06], [07] , [08]
HRI will not be printed if the value other than the listed above is specified.
[Notes]
If the value other than valid range is set, command error will occur and barcode will not be
printed.
Barcode will be printed even if the data exceed the printing area.
Increasing narrow bar width may exceed the print area.
Scanner may not read the barcode with valid character pitch when Character Pitch <P> is
increased. Also, increasing the narrow bar width may cause the same type of problem. For
more information, refer to the documentation of your scanner.
For specifying the narrow bar width, consider the reading compatibility of scanner and head
density beforehand.
Adjust Print Speed <CS> or Print Darkness <#F> if there is a problem in barcode reading.
Matrix 2of5 will be expressed as Coop2of5/NEC2of5.
If Start/Stop character is not included in print data at the time of CODABAR (NW-7) or CODE39
specified, barcode will be printed; however, scanner cannot read it.
If sending the print data including check digit at the time of JAN/EAN-13 or JAN/EAN-8
specified, set the correct calculated value. Barcode will be printed even when the data includes
improper check digit; however, scanner cannot read it.
Parent topic
Barcode Command
Ratio
Narrow
space width
2:5
2
<P>
Nil
2
<P>0
2
<P>1
1
<P>2
2
<P>3
3
<P>4
4
191
Inter-character gap
Narrow bar
Narrow bar
width: 1
width: 2
4
4
2
4
6
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents