[Sample of status reply1] (format set to ASCII)
When '4912345678904' and DSFID code 55H, AFI code 10H, and EAS bit 1 are recorded in the
RFID tag of ICODE SLI of "E004010001D9CA2D", UID :.
Command
Status reply [STX]22,02,UD:13,4912345678904[ETX]
Command
Status reply [STX]40,02,UD:13,4912345678904,DS:55,AF:10,EA:01[ETX]
[Sample of status reply 2] (format set to HEX)
When '4912345678904' is recorded in the RFID tag of Tag-it HF-I of "E00700002AC1E2BF", UID :.
(Data is not set to the optional flag data.)
Command
[DC2]PJ,H1,HX
Status reply [STX]22,03,ud:13,34393132333435363738393034[ETX]
Command
[DC2]PJ,H1,H2,HX
Status reply [STX]19,03,ud:13,34393132333435363738393034,UI:E00700002AC1E2BF[ETX]
[Sample of status reply 3]
When '4912345678904' and DSFID code 55H, AFI code 10H, and EAS bit 1 are recorded in the
RFID tag of ICODE SLI of "E004010001D9CA2D", UID :.
Command
[DC2]PJ,H2,NO
Status reply [STX]22,02,UI:E004010001D9CA2D[ETX]
Command
[DC2]PJ,H3,NO
Status reply [STX]20,02,DS:55,AF:10,EA:01[ETX]
Command
[DC2]PJ,H2,H3,NO
Status reply [STX]40,02,UI:E004010001D9CA2D, DS:55,AF:10,EA:01
[DC2]PJ,H1,AS
USER data
Inlet type (ICODE)
[DC2]PJ,H1,H3,AS
Inlet type (ICODE)
Inlet type (Tag-it)
Inlet type (ICODE)
UID data
Inlet type (ICODE)
Option flag data
Inlet type (ICODE)
UID data
Inlet type (ICODE)
USER data
Option flag data
USER data
USER data
Option flag data
572
UID data