SATO CL4NX Programming Reference Manual page 473

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

ams:
Specify the page to start ASCII
mirroring
amb:
Specify start byte for ASCII
mirroring
When specifying these parameters, it is necessary to consider the character number reflected by the user
data.
E.g.
NFC:2,ecd:0,lgc:en,ndd:28,AB:00000000000000x000000:EFG,amc:3,ams:0,amb:3
When accessing the tag with this setting, the following is reflected.
E.g.
UID:04-E1-41-12-4C-28-80, NFC counter:00-3F-31
「 AB:04E141124C2880x003F31:EFG」
UID
NFC counter
Separator
* For NTAG213, NTAG215 and NTAG216, the data specified by amc: is reflected. However, for NTAG210 and NTAG212, as
there is no NFC counter structurally, UID will be reflected automatically.
ame:
modulation mode
nce:
NFC counter update
Parameters related to ASCII mirroring (omissible)
UID
NFC counter
Separator
Parameters modulation mode (omissible)
Parameters related to NFC counter (omissible)
471
(UID 14 characters + NFC counter 6 characters + 1
separating character in between)
Specify which page to start reflecting from in the user
memory for the data specified with amc.
Valid range: 0-255, a 3-digit decimal
A parameter error will occur when a value that
exceeds specified inlet capacity is specified.
IC Chip type
Product
00
NTAG203
01
NTAG210
02
NTAG212
03
NTAG213
04
NTAG215
05
NTAG216
-: No ASCII mirroring
aSpecify start byte to reflect the page specified in
ams.
Valid range: 0 ~ 3
Defines the modulation mode.
Valid range: 0 or 1
0: strong modulation mode disabled.
1: strong modulation mode enabled.
CFG1:ACCESS:NFC_CNT_EN
Sets availability of NFC counter automatic update.
Valid range: 0 or 1
Valid range
-
0 to 11
0 to 31
0 to 35
0 to 123
0 to 221