[ESC+F] EPC sequential number (UHF M6e) (CL4NX Only)
Command
Hexadecimal code
Initial Value
Valid range and term of
command
[Function]
This command is set before EPC code write (<IP0> command), and is used to write the sequential
number of the specified data.
[Format]
<F>aaaabcccc(,dd,ee,f)
•
Parameter
aaaa "Number of printing for the same contents" = Valid range : 1 to 9999
b "Increment/decrement setting"
+ : Addition
- : Subtraction
cccc "Increment/decrement value setting" = Valid range : 1 to 9999
dd "Sequential numbering digits" = Valid range : 1 to 24 24 if omitted (can be omitted)
ee "Lower disabled digits" = Valid range : 0 to 99 0 if omitted (can be omitted)
f "Decimal or HEX serial number"
0 : Decimal 0 if omitted (can be omitted)
1 : HEX
[Coding Example]
Number of printing for the same contents: 1, Increment/Decrement: +, Increment/decrement value:
1, Sequential numbering digits: 5
Lower disabled digits: 0
<A>
<V>100<H>100<P>2<L>0202
<F>1+1,5,0<IP0>e:h,epc:0123456789ABCDEF01200000;
<Q>2
<Z>
[Supplemental explanation]
•
The EPC sequential number location in one item is one location.
•
Inverse printing <(> of the sequential number data cannot be used.
•
Automatic line feed <E> cannot be used.
•
EPC sequential numbering is enabled only if specified immediately before EPC code write
(<IP0> command).
•
This command cannot be used in items that include the <TU> command.
Parent topic
RFID Command (CL4NX Only)
ESC
<1B>
16
Nil
When turning off the power
Valid range within item
Valid range between items
423
F
<46>
16
The set command is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Parameter
aaaabccc(,dd,ee,f)