[ESC+BQ] QR Code (Compatible command)
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying QR code.
[Format]
[Manual setup] <BQ>abcc,(ddeeff,)g(hhhh)n
[Auto setup] <BQ>abcc,(ddeeff,)0n
•
Parameter
a [Error correction level]
1 : 7% High density level (L)
2 : 15% Standard level (M)
3 : 30% High reliability level (H)
4 : 15% High reliability level (Q)
b [Concatenation mode]
0 : Normal mode
1 : Concatenation mode
c [Size of one side of cell]
Valid Range : 01 to 99 (dot)
e.x.) cc=04
4 dots
d [No. of partitions by concatenation mode]
Valid range : 01 to 16
e [Sequential number partitioned by concatenation mode]
Valid range : 01 to 16
f [Concatenation mode parity data]
Valid range : 00 to FF
g [Character mode]
0 : Auto setup mode
1 : Number mode
2 : Alphanumeric mode
3 : Binary mode
4 : Kanji mode
h [No. of data]
Valid range : 0001 to 7366 (dot)
n [Print data] = Data
ESC
<1B>
16
Nil
When the power is OFF
Valid range within items
Valid range between
items
Feed direction
4 dots
BQ
<42>
<51>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
283
Parameter
Manual setup: abcc,
(ddeeff,)g(hhhh)n
Auto setup: abcc,(ddeeff,)gn