SATO CL4NX Programming Reference Manual page 589

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

[Sample of status reply 2] (format set to HEX)
When "4912345678904" is recorded on FeliCa Lite/FeliCa Lite-S block 8000H with IDm =
"03FEFFE0536C92A8", PMm = "03014B024F4993FF" and ID block = "3031323334353637
FFE0123456789ABC" (subtract block set to default)
Command
[DC2]PJ,F1,HX
Status reply [STX]22,04,ud:13,34393132333435363738393034[ETX]
Command
[DC2]PJ,F1,F2,HX
Status reply [STX]98,04,
Note: All data are continuous in reality.
[Sample of status reply 3]
When "4912345678904" is recorded on FeliCa Lite/FeliCa Lite-S block 8000H with IDm =
"03FEFFE0536C92A8", PMm = "03014B024F4993FF" and ID block = "3031323334353637
FFE0123456789ABC" (subtract block set to default)
Command
[DC2]PJ,F2,NO
Status reply [STX]78,04,
Note:All data are continuous in reality.
[Sample of status reply 4] (format set to ASCII)
When there is not an RFID tag or when an RFID tag is bad.
Command
Status reply [ [STX]2,06[ETX]
Command
Status reply [ [STX]2,06[ETX]
USER data
USER data
Inlet type (FeliCa Lite/FeliCa Lite-S)
Inlet type (FeliCa Lite/FeliCa Lite-S)
ud:13,34393132333435363738393034,
DM:03FEFFE0536C92A8,PM:03014B024F4993FF,
ID:3031323334353637FFE0123456789ABC[ETX]
Inlet type (FeliCa Lite/FeliCa Lite-S)
DM:03FEFFE0536C92A8,PM:03014B024F4993FF,
ID:3031323334353637FFE0123456789ABC[ETX]
[DC2]PJ,F1,AS
Inlet type (RFID tag none/reading error)
[DC2]PJ,FA,AS
Inlet type (RFID tag none/reading error)
USER data
ID data
ID data