[Supplementary Explanation]
When the value outside of the range is specified for pattern, it will be processed as "0". (This will
not be a command error.)
When the print start position exceeds the printing area, the printing is performed. (This will be a
command error.)
(When the print start position exceeds the printing area in the vertical direction, the label will be
fed.)
When the side length is not equal to the base length, printing will not be performed due to
command error.
This command sets the base reference point to the apex of a triangle.
0,0
<H>200
This command can be registered to the format.
If setting the line wider, it will be widened inward.
If the base length is odd number, +1 will be added automatically to make even number.
[Valid number]
Side length
10 to 2000
Parent topic
Modification Command
<V>100
a : Side length
b : Base length
a
a
b
1 to 1000
Valid range (dots)
Line width
49
Base length
10 to 2000